Power Range | 3 Phase 0,4~315 kW | ||
Power Supply Range | 3 Phase 380-480 V + - | ||
Control Mode | V/f control ,Vector control without speed sensor (Dynamic torque vector) V/f control with slip compensation , V/f control, with slip sensor(PG option) V/f Control with speed sensor (+Auto Torque Boost)(PG option) Vector control with speed sensor (PG option) Vector control without magnetic pole position sensor | ||
Frequency | 50/60 Hz +-%5 | ||
Overloadability | 0 for 1 minute (ND,HND) 0 for 1 minute, 200% for 3 sec. (HHD) 0 for 1 minute (HD) | ||
Ambient Operating Temperatue | -10 ~ +50C ( without derating) for HHD and HND / -10 ~ +40C ( without derating) for HD and ND | ||
Switching Frequency Range | FRN0022/0029/0037/0044/0059E2S-4E • 0.75 to 16 kHz variable (HHD/HND/HD mode) • 0.75 to 10 kHz variable (ND mode) FRN0072/0085/0105/0139/0168E2S-4E • 0.75 to 16 kHz variable (HHD mode) • 0.75 to 10 kHz variable (HND/HD mode) • 0.75 to 6 kHz variable (ND mode) FRN0203E2S-4E or above: • 0.75 to 10 kHz variable (HHD mode) • 0.75 to 6 kHz variable (HND/HD/ND mode) | ||
Maximum Output Frequency | HHD/HND/HD mode: 25 to 500 Hz variable (under V/f control, Magnetic pole position sensorless vector control) (Up to 200 Hz under vector control with speed sensor) ND mode: 25 to 120 Hz (under any drive control) | ||
Starting Torque | 200% or above, reference frequency 0.5 Hz (HHD-mode inverters of FRN0072E2S-4E or below) 150% or above, reference frequency 0.5 Hz (HHD-mode inverters of FRN0085E2S-4E or above) • 120% or above, reference frequency 0.5 Hz (HND/ND mode) • 150% or above, reference frequency 0.5 Hz (HD mode) | ||
Analog Input/Output | 3 Analog Input ( 0~-+10 VDC , 0~-+10 VDC , 4-20mA ) 1 Analog Output ( 0~-+10 VDC , 4-20mA programmable) Analog Input ( 0~-+10 VDC , 0(4)-20mA / 0~+10 VDC ) | ||
General Functions | Quad range, Customizable logic with 200 steps, PID, Brake control function | ||
Enclosure (IEC 60529) | IP20, IP00 |
3 AC 380V | |||||||||
PRODUCT CODE | HHD :High Heavy duty-0 for 1 min. , 0 for 0,5 sec. 50 C | HND :High Normal duty-0 for 1 min. , 50 C | HD :Heavy Duty-0 for 1 min. , 40 C | ND :Normal Duty-0 for 1 min. , 40 C) | DIMENSIONS(mm) Width X Height x Depth | ||||
POWER (kW) | CURRENT (A) | POWER (kW) | CURRENT (A) | POWER (kW) | CURRENT (A) | POWER (kW) | CURRENT (A) | ||
FRN0059E2S-4E | 18,5 | 39 | 22 | 45 | 22 | 45 | 30 | 59 | 250x400x195 |
FRN0072E2S-4E | 22 | 45 | 30 | 60 | 30 | 60 | 37 | 72 | 250x400x195 |
FRN0085E2S-4E | 30 | 60 | 37 | 75 | 37 | 75 | 45 | 85 | 326,2x550x261 |
FRN0105E2S-4E | 37 | 75 | 45 | 91 | 45 | 91 | 55 | 105 | 326,2x550x261 |
FRN0139E2S-4E | 45 | 91 | 55 | 112 | 55 | 112 | 75 | 139 | 361,2x615x276 |
FRN0168E2S-4E | 55 | 112 | 75 | 150 | 75 | 150 | 90 | 168 | 361,2x675x276 |
FRN0203E2S-4E | 75 | 150 | 90 | 176 | 90 | 176 | 110 | 203 | 361,2x740x276 |
* DC choke is a must to use for the power 75 kW and above. |